I had a guy ask me today about some funky output he was seeing on his router when he was trying to get info on his SFP optics from “show chassis hardware”. I directed him instead to check out “show chassis pic fpc-slot <#> pic-slot <#>”. It’s a lot more detailed and reliable.
–
user@host> show chassis pic fpc-slot 4 pic-slot 1
FPC slot 4, PIC slot 1 information:
Type 10x 1GE(LAN)
State Online
PIC version 0.0
Uptime 18 days, 5 hours, 41 minutes, 54 seconds
PIC port information:
Fiber Xcvr vendor
Port Cable type type Xcvr vendor part number Wavelength
0 SFP-1000BASE-BX10-D SM SumitomoElectric SBP6H44-J3-BW-49 1490 nm
1 SFP-1000BASE-BX10-D SM SumitomoElectric SBP6H44-J3-BW-49 1490 nm
2 SFP-1000BASE-BX10-D SM SumitomoElectric SBP6H44-J3-BW-49 1490 nm
3 SFP-1000BASE-BX10-D SM OCP TRXBG1LXDBVM2-JW 1490 nm
4 SFP-1000BASE-BX10-D SM OCP TRXBG1LXDBVM2-JW 1490 nm
5 SFP-1000BASE-BX10-U SM SumitomoElectric SBP6H44-J3-BW-31 1310 nm
6 SFP-1000BASE-BX10-U SM SumitomoElectric SBP6H44-J3-BW-31 1310 nm
7 SFP-1000BASE-BX10-U SM OCP TRXBG1LXDBBMH-J1 1310 nm
8 SFP-1000BASE-BX10-U SM OCP TRXBG1LXDBBMH-J1 1310 nm
9 SFP-1000BASE-BX10-U SM SumitomoElectric SBP6H44-J3-BW-31 1310 nm